 Switching Spark Gap
FS08X-1GH Ordering code: B88069X0340XXXX a)
Nominal breakdown voltage VN Initial values 2) Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV Electrical life time 3) Breakdown voltage VB up to 100 000 Ignitions First ignition value VB, FTE after 24 hours in darkness Ignition time tI at V0 during life Following ignition values VB, FIV at 50 000 Ignitions Following ignition values VB, FIV Switching operations in total at - 40; +150 C, each at + 25; +125 C, each Test circuit parameters Open circuit voltage V0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP General technical data Insulation resistance at 100 V Early ignition values between 530 ... 680 V Breakdown time Maximum loading current Weight Marking, blue
800
V
950 704 ... 896
V V
1000 60 704 ... 920 680 ... 920 100 000 10 000 40 000 1000 56 114 0.13 ~ 660 > 100 1 50 50 ~2
800 WW Y O
V ms V V Ignitions Ignitions Ignitions V k nF H A M % ns mA g 800 WWY O
- Nominal voltage - Calendar week of production - Year of production - Non radioactive
a)
xxxx = T502 (taped and reeled with 500 pcs.) = T103 (taped and reeled with 1000 pcs.) At delivery AQL 0,65 level II, DIN ISO 2859 Page 2, Fig. 1 and 2 Page 2, Fig. 3 and 4
1) 2) 3)
KB AB E / KB AB PM Page 1 of 2
Issue 07, 16.06.2004
Switching Spark Gap
FS08X-1GH Ordering code: B88069X0340XXXX a)
Fig. 1: QC- test circuit (100% outgoing inspection)
I = const 51k
Fig. 2: Explanation of measurands
VS, FTE VS VS, FIV
0,22F
DUT
VS
VN
t ICU - VN
DUT device under test ICU ignition control unit (sensitivity 10 .. 30 A) Discharge current 10 - 20 mA Fig. 3: QC- test circuit (sampling inspection at 25 C)
R L VB VN VO C DUT VB
dVS/dt ~ dVN/dt Fig. 4: Explanation of measurands
VB, FTE Range of VB, FIV Early ignition VB, FTE
t tI 1s 10 s
Not to scale Dimensions in mm Non controlled document
EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. KB AB E / KB AB PM Page 2 of 2 Issue 07, 16.06.2004


▲Up To Search▲   

 
Price & Availability of B88069X0340XXXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X